PCI "Campanil"TR 259 Analogic
Setting the clock
Press the control knob and turn clockwise.
Alarm programme adjustement
Turn the knob clockwise without pressing it in. At the end of the
programmed time an alarm will sound. To cancel it, turn the knob
to the bell.
XII
XI
X
IX
VIII
VII
VI
V
I
II
III
IV
N
H05 RR-F
H05 RR-F
GB
REPLACEMENT OF THE CABLE
In case the cable is damaged, replace it in accordance with the
following instructions:
- open the box of the supply board as described on the picture
below;
- unscrew screw “A” fixing the cable;
- replace the cable with one of the same lenght and in accordance
with the features described on the table; switch the appliance
off, and close the gas tap
- the ‘green-yellow” earth wire must be connected to the terminal
“ and it must be about 10 mm longer thean the live wires;
- the “blue” neutral wire must be connected to the terminal marked
with letter “N”;
- the live wire must be connected to the terminal marked with letter
“L”.
Applance type Supply single-phase 220-230 V~
Type of cable section
All gas Rubber H05 RR-F 3 x 0,75 mm
2
All gas + electric grill Rubber H05 RR-F
3 x 2,5 mm
2
XII
XI
X
IX
VIII
VII
VI
V
I
II
III
IV
ELECTRICAL CONNECTION
Connection of the appliance to the power mains should be done
by a licensed electrician familiar with local safety regulations.
This appliance must be earthed by law. Before connecting
the appliance to the electrical supply, check that the earth
system in your house is working correctly.
Check that unit voltage and power, marked on the rating plate
applied on the appliance, are correct for the supply. It is necessary
that the feeding network is protected by a powerful switch able
to disconnect completely the network with a contacts separation
of at least 3 mm. Be sure that the earth wire green/yellow is
not interrupted by the switch.
Important: The wires in the mains lead are so coloured:
- green/yellow = earth " "
- blue = neutral “N”
- brown = live “L
The wire coloured green/yellow must be connected to the terminal
in the plug which is marked with letter 'E' or by the earth symbol
or coloured green or green/yellow. The wire coloured blue
must be connected to the terminal which is marked with letter 'N'
or coloured black. The wire coloured brown must be connected
to the terminal which is marked with letter 'L' or coloured red. The
supply cable must not come into contact with any component the
temperature of which exceeds the ambient temperature by 50°C.
If a plug is used for connection, the plug to be connected to the
supply cable and the socket to which it is connected must be of
the same type (conforming to the standards). Easy access to the
plug or the switch is ensured once the appliance is installed.
Ensure that there is sufficient cable allowed for any subsequent
removal of the unit. If the plug is non-rewireable, pay attention
to the following points: the plug must never be cut by the supply
cord. There is shock hazard when this plug is inserted in a socket-
outlet elsewhere in the house. Never use the plug without the
fuse cover fitted. Referring to the pertinent spare parts, apply to
the appliance's supplier. The manufacturer declines all
responsibility for any damage to persons or things caused