Install correctly to give shock protection.
Loose and incorrect plug and socket connections can make the terminal become too hot.
A qualified electrician must install the connections in the clamps correctly.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
Assembly
min.
50mm
min.
50mm
min.
500mm
600 mm
560
+1
mm
R5
490
+1
mm
min.
28 mm
14 Installation instructions