ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
6.8 TOR – Maximum Reading Time
Timeout for the reader. TOR is used in operation mode 2 as maximum gating time for a
reading process . The length of the maximum gating time results from the equation gat-
ing_time = TOR * TB.
The time constant TB (Time Base) has always the default value 100ms.
Input format: TOR <SP> parameter <CR>
Parameter:
Function
0 limits the reading process duration to exactly one reading cycle
1 limits the reading process duration to maximum 1 times TB
2 limits the reading process duration to maximum 2 times TB
...
255 limits the reading process duration to maximum 256 times TB
Output (example): 2 <CR>
6.9 VS- Show Parameter
The command VS lists all current parameter settings.
Input format: VS <CR>
Output (example): EC <SP> 0 <CR>
BD <SP> 2 <CR>
MD <SP> 2 <CR>
6.10 VSAVE – Save Parameter
All operating parameters temporarily stored are saved permanently using VSAVE.
Input format: VSAVE <CR>
Output: ok <CR>